Title of article :
Effect of ozonation for reducing membrane-fouling in the UF membrane Original Research Article
Author/Authors :
Young G. Park، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
6
From page :
43
To page :
48
Abstract :
The effect of ozonation on permeate flux was studied by using a polysulfone ultrafiltration membrane. The filtration was carried out by permeating chemical wastewater treated by combined ozone and membrane filtration methods under 3 kgf/cm2 until steady-state flux was obtained. Then, the ozone of concentration range between 10 and 45 mg/l×min was ozonated in water for reducing the fouling on the UF membrane. It was found that the ozonation made the permeate flux enhance by 10%, and oxidation by ozone and hydrogen peroxide was more effective. Evidence was presented that TMP decreased in more ozone-concentrated water and it was found that the ozone-mediated membrane would have a limited role to prevent membrane fouling rather than to eliminate it fully.
Keywords :
Chemical wastewater , Ozone , Membrane process
Journal title :
Desalination
Serial Year :
2002
Journal title :
Desalination
Record number :
1107820
Link To Document :
بازگشت