• Title of article

    Pilot-scale testing of reverse osmosis using conventional treatment and microfiltration Original Research Article

  • Author/Authors

    Christopher J. Gabelich، نويسنده , , Tae I. Yun، نويسنده , , Bradley M. Coffey، نويسنده , , I.H. (Mel) Suffet، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    17
  • From page
    207
  • To page
    223
  • Abstract
    In order to meet the growing needs of its consumers, the Metropolitan Water District of Southern California is looking for ways to desalt water from the relatively hard Colorado River. This study evaluated conventional treatment as the pretreatment step for reverse osmosis (RO) desalting. Other pretreatment options studied include microfiltration (MF) and conventional treatment with ozone and biologically active filters. Each of three pretreatment scenarios produced effluent waters generally considered appropriate for use with RO [median turbidity of less than 0.1 Nephelometric turbidity unit (NTU) and median silt density index of less than 3]. Both microfiltered and ozonated/ biofiltered waters gave steady RO performance over 3 months of testing. However, conventional treatment left the RO system vulnerable to organic and biological fouling. Despite maintaining a 2-2.5 mg/L chloramine residual, pretreatment using conventional treatment required more frequent cleanings than either MF or ozonation/biofiltration (O3/BF). The good performance for biofiltered water may have resulted from the stabilization of the natural organic matter through the O3/BF process. Microfiltration, with its superior particle and bacteriological removal characteristics, provided the best RO pretreatment technology.
  • Keywords
    Organic fouling , Biological fouling , Conventional treatm , Reverse osmosis
  • Journal title
    Desalination
  • Serial Year
    2003
  • Journal title
    Desalination
  • Record number

    1108200