• Title of article

    Comparison of three pilot studies using Microza® membranes for Mediterranean seawater pre-treatment Original Research Article

  • Author/Authors

    D. Vial، نويسنده , , G. Doussau، نويسنده , , Gabriel R. Galindo، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    8
  • From page
    43
  • To page
    50
  • Abstract
    Until recently, in desalination plants seawater was pre-treated with a combination of conventional techniques such as air flotation, clarification, sand filtration and cartridge filtration prior to spiral wound reverse osmosis desalination membranes. Microfiltration or ultrafiltration membranes are now considered as an alternative solution for seawater pre-treatment. This paper describes pilot test results obtained at three different locations treating Mediterranean seawater using 0.1 μm hollow fiber membranes in Pallʹs Microza modules. Depending of the location, the pilots operated with or without pretreatment using ferric chloride and with or without specific flux maintenance (SFM) protocols performing daily highly chlorinated backwash. The study shows that system optimization yields stable, reproducible permeate flow and permeate SDI of 1.8 or less, with mean SDI of 1.43 when seawater was coagulated or SFM was performed. At these conditions, reverse osmosis system recovery is enhanced and total integrated system performance is optimized.
  • Keywords
    Reverse osmosis , Pre-treatment , Seawater , SDI , Desalination , Microfiltration , Ultrafiltration
  • Journal title
    Desalination
  • Serial Year
    2003
  • Journal title
    Desalination
  • Record number