Title of article :
Performance evaluation of a small size TVC desalination plant Original Research Article
Author/Authors :
Walid El-Mudir، نويسنده , , Mohamed El-Bousiffi، نويسنده , , Salah Al-Hengari، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
11
From page :
269
To page :
279
Abstract :
This paper is concerning the performance evaluation of small size thermal vapour compression (TVC) desalination units. The plant consists of two identical vapour compression units, each of a nominal capacity of 375 m3/d of distillate water. Despite the fact that these units are fairly new (two years in operation at time of evaluation), some operating problems were experienced. In this study, some important design factors and operating conditions are reviewed and the plant operating data were used to evaluate the unit performance. Conclusions derived from this evaluation are presented with emphasis on plant economy.
Keywords :
Plant evaluation , Performance factors , TVC
Journal title :
Desalination
Serial Year :
2004
Journal title :
Desalination
Record number :
1108604
Link To Document :
بازگشت