Title of article :
Separation of some light monocarboxylic acids from water inbinary solutions in a reverse osmosis pilot plant Original Research Article
Author/Authors :
Vittorio Ragaini، نويسنده , , Carlo Pirola، نويسنده , , Alessandro Elli، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
12
From page :
21
To page :
32
Abstract :
The separation of formic (C1), acetic (C2), propionic (C3), and n-valeric (C5) acids in binary water solutions has been studied using a reverse osmosis (RO) membrane pilot plant operating at different temperatures and pressures (usually 21 °C and 1.72 MPa). The RO membrane, which is composite, polyamide and spiral-wound, having a surface area of 2.6 m2, was fed by a solution of 0.5 M of C1, C2 and C3 acids and 0.146 M of C5. The pilot plant was used to simulate a cascade series of RO modules by recycling the permeate flux at the end of each semi-batch run. The influence on the retention coefficient, R, of molecular weight and molar volume, pKa of the different acids was determined. For acetic acid the influence of temperature (T) and transmembrane pressure (ΔP) was also studied, obtaining an inverse and direct good linear correlation for R vs. T and R vs. ΔP, respectively. The results are particularly interesting for acetic acid-water separation, which is an open question in industrial applications.
Keywords :
Acid , Reverse osmosis , Carboxylic , Separation , Acetic