Title of article :
Study on the cleaning of new ultrafiltration spiral-woundmodules to prevent membrane fouling (including biological fouling) Original Research Article
Author/Authors :
St. Pavlova، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
4
From page :
267
To page :
270
Abstract :
A study of cleaning a Bulgarian OF 60 PAN spiral-wound module was carried out on an ultrafiltration unit(Millipore, USA). Chemical cleaning of the membrane with a 0.25% solution of sodium metabisulfite did not prevent biological fouling. When treated with a 1% solution of formaldehyde, membrane fouling was diminished and the ultrafiltrate obtained contained a significantly lower number of microorganisms and colloid formations including iron and humic acids. After treatment with the two cleaning agents, the membrane maintained its flux for the water studied within a range of 1.58 to 1.64 m3/m2/d. The effect on the contaminants to be removed was also found to be comparatively constant. Membrane selectivity remained constant at different permeate yields.
Keywords :
Ultrafiltration spiral-wound membranes , Fouling , Membrane cleaning
Journal title :
Desalination
Serial Year :
2005
Journal title :
Desalination