• Title of article

    Development of an ion exchange system for plating wastewater treatment Original Research Article

  • Author/Authors

    Tae-Hyoung Eom، نويسنده , , Chang-Hwan Lee، نويسنده , , Jun-Ho Kim، نويسنده , , Choul-Ho Lee، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    10
  • From page
    163
  • To page
    172
  • Abstract
    Ion exchange technology was applied to this study to treat nickel ion from plating wastewater which contains heavy metal, bringing environmental problems such as chromium, zinc, copper, and lead. To separate nickel ion from wastewater, the nickel recovery unit (NRU) used a column packed with strongly acidic cation resin. The leak of the ion appeared when rinse water that has a concentration of 1.8 g-Ni/L-distilled water flowed into the NRU as much as 20 times the bed volume. At this time, the capacity of resin packed in the column was 1.7 meq/ml and over 99% nickel ion was removed. Sulfuric acid was employed with a reagent in order to regenerate nickel ion from the resin adsorbed. Nickel ion recovered by sulfuric acid was obtainable up to 120 g-Ni/L. The concentration of sulfuric acid was 2N and space velocity was 2/h. Acid retardation unit (ARU) experiment could be accomplished by deacidification to control the pH of the solution to recycle in the plating process. The composition was 30 g-Ni/L and the pH maintained was over 3.0.
  • Keywords
    Acid retardation unit , Ion exchange system , Ion exchange technology , Plating waste water , Nickel recovery unit
  • Journal title
    Desalination
  • Serial Year
    2005
  • Journal title
    Desalination
  • Record number

    1109238