• Title of article

    Enhancing permeate flux in a RO plant by controlling membrane fouling Original Research Article

  • Author/Authors

    M.C. Amiri، نويسنده , , M. Samiei، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    9
  • From page
    361
  • To page
    369
  • Abstract
    Concentration polarization near the membrane surface increases local trans-membrane osmotic pressure and solute passage. It is governed by solute properties, membrane properties and hydrodynamics. Increasing the feed velocity confines the affected area to a thinner layer and usually results in reducing membrane fouling and scaling phenomena. Higher feed velocity reduces scaling and fouling. The results of fouling control by changing softening process from lime to caustic regime have been outlined in this work in the reverse osmosis (RO) units that treat brackish water for producing 400 m3/h industrial water. Performances of these RO units were not satisfactory for many months due to high tendency in membrane fouling even following the recommendations of membrane supplier. Therefore, a new softening method has been applied successfully for enhancing the RO plant performance. This improvement in performance of RO units clearly justifies the importance of softening regime as a key parameter in fouling control.
  • Keywords
    Concentration polarization , RO , Performance analysis , Scale , Membrane fouling
  • Journal title
    Desalination
  • Serial Year
    2007
  • Journal title
    Desalination
  • Record number