Title of article
RO membrane autopsy of Zarzis brackish water desalination plant Original Research Article
Author/Authors
Mohamed Karime، نويسنده , , S. Bouguecha، نويسنده , , B. Hamrouni، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
9
From page
258
To page
266
Abstract
Tunisia, located in a semi-arid zone, has limited water resources. The shortage of good water quality in particular at the south regions required a brackish water desalination to supply these regions with potable water. Zarzis desalination plant, working since 1999, has revealed difficulties related to the loss of membrane performances. In the aim to determine the reason of membrane fouling, foulant layer were analysed. The membrane autopsy has achieved by different methods, such as TOC (total organic carbon) measurement, SEM (scanning electron microscopy), AFM (atomic force microscopy), FTIR (fourier transform infrared spectroscopy) analysis, diffraction by X-ray. Results show that the foulant layer composed mostly of SiO2, clay, organic matter (polysaccharide, protein), CaSiO3, Fe3O4, AlPO4, and CaSO4. The characteristics bonds obtained by IR indicate the presence of polysaccharides and proteins that constitute a source for further microbiological growth; this is the problem of biofouling. The metallic elements results of corroded stainless steel and internal coating of cartridges filter that are damaged by the silica particle rejected by sand filters. The scale of CaSO4 and CaSiO3 deposition is owing to the bad antiscaling efficiency. The results are presented and discussed in the light of new trends in material.
Keywords
Fouling , Autopsy , Reverse osmosis membrane , Antiscaling , Desalination plant
Journal title
Desalination
Serial Year
2008
Journal title
Desalination
Record number
1111258
Link To Document