Title of article
Factors affecting phenol transfer through polydimethylsiloxane composite membrane Original Research Article
Author/Authors
Mao-Sung Lee، نويسنده , , Chihpin Huang، نويسنده , , Kueir-Rarn Lee، نويسنده , , Jill R. Pan، نويسنده , , Wang-Kuan Chang، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
10
From page
416
To page
425
Abstract
Polydimethylsiloxane composite membrane was employed for the separation of phenol and sodium chloride in synthetic wastewater. The major operational parameters affecting phenol transfer through this composite membrane were screened by the orthogonal array and range analysis. The results showed that the significance of parameters on the permeate flux followed the order of phenol concentration, membrane skin layer thickness, recirculation rate, and sodium chloride concentration after 6 and 48 h operations. Optimal operation range was determined by the response surface methodology coupled with central composite design. The higher was the phenol concentration in the influent or the thicker was the membrane skin layer thickness, the higher was the permeate flux throughmembrane. Also, the higher was the recirculation rate, the higher was the permeate flux through membrane.
Keywords
Wet-phase inversion , Extractive membrane , Phenol , Permeation , Range analysis
Journal title
Desalination
Serial Year
2008
Journal title
Desalination
Record number
1111912
Link To Document