Title of article :
Removal of bacterial and viral indicator in vertical flow constructed wetlands and intermittent sand filters Original Research Article
Author/Authors :
Antonina Torrens، نويسنده , , Pascal Molle، نويسنده , , Catherine Boutin، نويسنده , , Miquel Salgot، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
10
From page :
169
To page :
178
Abstract :
The removal of faecal coliforms (FC), Escherichia coli, somatic coliphages and F-specific bacteriophages was monitored over a period of 2 years in two vertical flow constructed wetlands (VFCWs) and four intermittent sand filters (ISFs) that treat pond effluent. Tracer tests (NaCl) were performed to estimate the hydraulic retention time (HRT) of the filters. The contribution of Phragmites australis to the removal of the faecal indicators was examined. The effect of media characteristics (depth, type of sand), hydraulic load and water application schedule on disinfection was also addressed. Planted and non-planted vertical sand filters were equally effective in removing microorganisms. The disinfection capacity was very sensitive to the depth and operation of the filters. HRT was the key parameter regarding filter disinfection capacity. Bacterial indicators were removed at a higher rate than viral ones. Somatic coliphages were removed at higher rates than F-specific bacteriophages.
Keywords :
E. coli , Faecal coliforms , Phages , Hydraulic retention time , Sand filters , Wetlands
Journal title :
Desalination
Serial Year :
2009
Journal title :
Desalination
Record number :
1112384
Link To Document :
بازگشت