Title of article :
Cathodic protection system of copper–zinc–saline water in presence of bacteria Original Research Article
Author/Authors :
Aprael S. Yaro، نويسنده , , Haidar Al-Jendeel، نويسنده , , Anees A. Khadom، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
Rate of zinc consumption during the cathodic protection of copper pipeline which carries saline water was measured by weight loss technique in the absence and presence of bacteria. Variables studied were solution flow rate, temperature, time and NaCl concentration. It was found that within the present range of variables; the rate of zinc consumption increases with the increase of all operating conditions. The presence of bacteria increases the zinc consumption. Fourth order multi-term model and one-term model were suggested to represent the consumption data. Nonlinear regression analysis was used to estimate the coefficients of these models, while statistical analysis was used to determine the effect of each coefficient. Both models were representing the data successfully.
Keywords :
Cathodic protection , Microbiological corrosion , Weight loss , zinc , copper
Journal title :
Desalination
Journal title :
Desalination