Title of article :
Membrane autopsy of a 10 year old hollow fibre membrane from Sydney Olympic Park water reclamation plant Original Research Article
Author/Authors :
S. Phuntsho، نويسنده , , A. Listowski، نويسنده , , H.K. Shon، نويسنده , , P. Le-Clech، نويسنده , , S. Vigneswaran، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
241
To page :
247
Abstract :
Membrane autopsy was performed for a 10 year old polypropylene (PP) hollow fibre microfiltration membrane from Sydney Olympic Park water reclamation plant. The properties of the membrane were studied using scanning electron microscope (SEM) imaging, contact angle, bubble test, thermogravimetric analysis, tensile strength test and functional group. The old and fouled membrane exhibited a significant difference in surface properties and material strength in comparison to the virgin membrane. The old and fouled membrane surface is less hydrophilic and less negatively charged indicating that aged membrane is more vulnerable to fouling than virgin membrane. The fibre material of the old fouled membrane appears less flexible and brittle. Foulant analysis indicated that major components of the metallic elements were silicon and calcium. The dissolved organic matter was mainly composed of biopolymers (hydrophilic) and humic substances (hydrophobic).
Keywords :
Membrane fouling , Membrane autopsy , Organic and inorganic foulant , Hollow fibre membrane
Journal title :
Desalination
Serial Year :
2011
Journal title :
Desalination
Record number :
1114425
Link To Document :
بازگشت