• Title of article

    Relationships between mixed liquor properties, operating conditions and fouling on two full-scale MBR plants Original Research Article

  • Author/Authors

    F. Delrue، نويسنده , , A.E. Stricker، نويسنده , , M. Mietton Peuchot، نويسنده , , Y. Racault، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    11
  • From page
    9
  • To page
    19
  • Abstract
    Two full-scale membrane bioreactors (MBRs) were monitored to investigate the impact of mixed liquor properties and operating conditions on the filtration performance. Large differences were observed between the two MBRs. At the Guéthary MBR, the F:M ratio increased gradually up to a factor of 2.5, but no impact was observed on the filtration process, even though the mixed liquor resistance to filtration increased. However the diluted sludge volume index (DSVI) and the protein concentration in the mixed liquor supernatant were correlated to the filtration performance. In comparison, none of the mixed liquor properties seemed to impact the filtration process at the Grasse MBR, which was subjected to sudden changes in biological and filtration operating conditions: one of the two aeration tanks was taken off line during two months, and the setpoint for coarse bubble air flow rate was changed 3 times. Nevertheless, the mixed liquor properties were affected by the changes in the biological process and the filtration performance responded to changes in the coarse bubble air flow rate. This work clearly demonstrated the strong impact of the operating strategy and the difficulty to generalize the results of fouling studies between full-scale plants, and from lab/pilot scale to full-scale.
  • Keywords
    Fouling , Full-scale , Membrane BioReactor , Operating conditions , Mixed liquor properties
  • Journal title
    Desalination
  • Serial Year
    2011
  • Journal title
    Desalination
  • Record number

    1114440