Title of article :
Preconcentration and determination of lead and cadmium in water samples with a MnO2 coated carbon nanotubes by using ETAAS Original Research Article
Author/Authors :
Binwu Yang، نويسنده , , Qiaojuan Gong، نويسنده , , Liping Zhao، نويسنده , , Hong Sun، نويسنده , , Ningning Ren، نويسنده , , Jinxin Qin، نويسنده , , Jie Xu، نويسنده , , Haiying Yang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
5
From page :
65
To page :
69
Abstract :
A procedure for separation and preconcentration trace amount of Pb(II) and Cd (II) by nano-sized manganese dioxide functionalized multi-wall carbon nanotubes (MnO2/MWCNTs) packed column has been proposed. Various influencing parameters on the separation and preconcentration of trace metals, such as pH, flow rate, concentration of eluent, sample volume and interference ions, were studied. Under the optimized conditions (pH 6, flow rate 2.5 mL min− 1), Pb(II) and Cd (II) were retained on the column, then quantitatively eluted by 1.5 mL 1.5 mol L− 1 nitric acid solution and determined by electrothermal atomic absorption spectroscopy (ETAAS). The detection Limits of Pb(II) and Cd(II) for an extraction of 5.0 mL water sample were 4.4 and 1.5 ng L− 1, respectively. The relative standard deviations (R.S.D.) were 3.2% and 2.5% for Pb(II) and Cd(II), respectively. The optimized method was successfully applied to the determination of Pb(II) and Cd(II) in certified reference materials and real water samples.
Keywords :
MnO2/MWCNTs , lead , cadmium , ETAAS , Solid phase extraction
Journal title :
Desalination
Serial Year :
2011
Journal title :
Desalination
Record number :
1114769
Link To Document :
بازگشت