Title of article :
Effects of temperature and biomass concentration on the performance of anaerobic sequencing batch reactor treating low strength wastewater Original Research Article
Author/Authors :
Birol Kayranli، نويسنده , , Aysenur Ugurlu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
7
From page :
77
To page :
83
Abstract :
The studies were carried out with simulated domestic wastewater (300±10 and 500 mg COD/L) and real domestic wastewater (290±10 mg COD/L). During these studies different organic loading rates (0.29, 0.82 and 1.1 kg COD/m3d for Set I and Set II, and 0.29 and 0.62 kg COD/m3d for Set III), hydraulic retention times (11, 15, 25 h), temperatures (10, 15, 25 °C) and at different anaerobic sludge concentrations (about 5, 10 g VSS/L) in the reactor were applied and the performance of the reactor was tested. It was observed that treatment of low strength wastewaters under low temperature was possible. Even at the lowest temperature applied and lowest sludge amount the total organic matter (COD) removal was 65.2%. However, the COD removal and methane production decreased with decreasing temperature and HRT. The COD removal efficiencies decreased when the system was fed with settled real domestic wastewater probably due to more complex structure of the domestic wastewater and the presence of suspended solids even in small concentrations. These results showed that the ASBR process can be used for treatment of low strength wastewaters at low temperatures.
Keywords :
Domestic wastewater , Low temperature , Anaerobic treatment , Anaerobic sequencing batch reactor , Low strength wastewater
Journal title :
Desalination
Serial Year :
2011
Journal title :
Desalination
Record number :
1114772
Link To Document :
بازگشت