• Title of article

    The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

  • Author/Authors

    ريوف، مريم نويسنده دانشكده دندانپزشكي، دانشگاه علوم پزشكي كرمان Raoof, M. , راد، مريم نويسنده , , منصوري، محمد رسو.ل نويسنده Oral and Dental Diseases Research Center Mansoori, Mohammad Rasoul , عسكري فرد، سارا نويسنده Oral and Dental Diseases Research Center Askarifard, Sara , نورزاده، مهديه نويسنده Department of Endodontics, Zanjan University of Medical Sciences Nourzadeh, Mahdieh , شكوهي نژاد، نوشين نويسنده دانشكده دندانپزشكي، دانشگاه علوم پزشكي تهران , , سماني پور، سيامك نويسنده Oral and Dental Diseases Research Center AND Kerman Social Determinants on Oral Health Research Center Samani-Poor, Siamak

  • Issue Information
    دوفصلنامه با شماره پیاپی 0 سال 2013
  • Pages
    8
  • From page
    81
  • To page
    88
  • Abstract
    BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was determined visually under a microscope. The teeth were embedded in an alginate model. NaOCl concentrations of 5.25%, 2.60%, and 2.00% chlorhexidine with three endodontic needles (21, 25, and 30 gauges) were delivered into the root canals of teeth in each group. Electronic length was determined with both devices using K-files of size 10. The results obtained with electronic apex locators were compared with the corresponding actual length. A multivariate linear regression model was used to determine the variables influencing the accuracy of the Root ZX II and Root ZX mini apex locators. RESULTS: Irrigant solution concentrations had no effect on the accuracy of the measurements with these locators (P = 0.83). The statistical analysis of the results showed EAL accuracy to be 100% for both Root ZX and Root ZX mini, within a tolerance of ± 0.5 mm. Data were analyzed by ANOVA. Multivariate linear regression model demonstrated that needle-insertion depths influenced the electronic measurements (P = 0.05), while the concentrations of irrigants did not influence the results. CONCLUSION: Under the conditions of this ex vivo study, needle-insertion depths influenced the electronic measurements.
  • Journal title
    Journal of Oral Health and Oral Epidemiology
  • Serial Year
    2013
  • Journal title
    Journal of Oral Health and Oral Epidemiology
  • Record number

    1114872