Title of article
The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
Author/Authors
ريوف، مريم نويسنده دانشكده دندانپزشكي، دانشگاه علوم پزشكي كرمان Raoof, M. , راد، مريم نويسنده , , منصوري، محمد رسو.ل نويسنده Oral and Dental Diseases Research Center Mansoori, Mohammad Rasoul , عسكري فرد، سارا نويسنده Oral and Dental Diseases Research Center Askarifard, Sara , نورزاده، مهديه نويسنده Department of Endodontics, Zanjan University of Medical Sciences Nourzadeh, Mahdieh , شكوهي نژاد، نوشين نويسنده دانشكده دندانپزشكي، دانشگاه علوم پزشكي تهران , , سماني پور، سيامك نويسنده Oral and Dental Diseases Research Center AND Kerman Social Determinants on Oral Health Research Center Samani-Poor, Siamak
Issue Information
دوفصلنامه با شماره پیاپی 0 سال 2013
Pages
8
From page
81
To page
88
Abstract
BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on
the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants.
METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of
the canals was preflared, and the length to the major foramen was determined visually under a microscope. The teeth
were embedded in an alginate model. NaOCl concentrations of 5.25%, 2.60%, and 2.00% chlorhexidine with three
endodontic needles (21, 25, and 30 gauges) were delivered into the root canals of teeth in each group. Electronic length
was determined with both devices using K-files of size 10. The results obtained with electronic apex locators were
compared with the corresponding actual length. A multivariate linear regression model was used to determine the
variables influencing the accuracy of the Root ZX II and Root ZX mini apex locators.
RESULTS: Irrigant solution concentrations had no effect on the accuracy of the measurements with these locators
(P = 0.83). The statistical analysis of the results showed EAL accuracy to be 100% for both Root ZX and Root ZX mini,
within a tolerance of ± 0.5 mm. Data were analyzed by ANOVA. Multivariate linear regression model demonstrated
that needle-insertion depths influenced the electronic measurements (P = 0.05), while the concentrations of irrigants did
not influence the results.
CONCLUSION: Under the conditions of this ex vivo study, needle-insertion depths influenced the electronic measurements.
Journal title
Journal of Oral Health and Oral Epidemiology
Serial Year
2013
Journal title
Journal of Oral Health and Oral Epidemiology
Record number
1114872
Link To Document