• Title of article

    Volatile organic compound removal by membrane gas stripping using electro-spun nanofiber membrane Original Research Article

  • Author/Authors

    Chaoyang Feng، نويسنده , , K.C. Khulbe، نويسنده , , Shahram Tabe، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2012
  • Pages
    5
  • From page
    98
  • To page
    102
  • Abstract
    Removal of volatile organic compound (chloroform) from water was carried out by membrane gas stripping using electro-spun poly(vinylidene fluoride) (PVDF) nanofiber membrane. It was shown that the process was feasible. The overall mass transfer coefficient of chloroform through the nanofiber membrane was found to be 2 × 10− 5 m/s at room temperature, which was more than the highest value obtained earlier for a hollow fiber air-stripping system. The activation energy of the mass transfer coefficient was almost the same as that of the Henry constant for chloroform absorption in water. It was therefore concluded that the chloroform desorption from water was the governing factor of the system.
  • Keywords
    Water treatment , Volatile organic compound , Membrane air striping , Nanofiber membrane
  • Journal title
    Desalination
  • Serial Year
    2012
  • Journal title
    Desalination
  • Record number

    1115238