Title of article :
Rheological investigation of pitch materials: Part I: Design and development of a high-temperature high-pressure (HTHP) rheometer Original Research Article
Author/Authors :
Pravin M. Khandare، نويسنده , , John W. Zondlo، نويسنده , , Peter B. Stansberry، نويسنده , , Alfred H. Stiller، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
881
To page :
887
Abstract :
A high-temperature, high-pressure (HTHP) rheometer is designed and developed to measure viscosity of pitch material at elevated temperatures. Although not demonstrated herein, the provision for high-pressure operation is made so that the effect of a dissolving gas on the viscosity of the pitch materials can be evaluated. The HTHP viscometer is constructed from a commercial high-pressure vessel (Autoclave Engineers, Inc.). The high-pressure vessel is rated for 7.6 MPa at 295 K with a maximum temperature limit of 773 K. The viscometer is calibrated using standard viscosity fluids at varying temperatures.
Keywords :
A. Pitch , C. Rheometry
Journal title :
Carbon
Serial Year :
2000
Journal title :
Carbon
Record number :
1118159
Link To Document :
بازگشت