• Title of article

    Ultralow magnetic fields and Gravity Probe B gyroscope readout Original Research Article

  • Author/Authors

    J.C. Mester، نويسنده , , J.M. Lockhart، نويسنده , , B. Muhlfelder، نويسنده , , D.O. Murray، نويسنده , , M.A. Taber، نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 2000
  • Pages
    4
  • From page
    1185
  • To page
    1188
  • Abstract
    We describe the generation of an ultralow magnetic field of < 10−11 Tesla in the flight dewar of the Gravity Probe B Relativity Mission. The field was achieved using expanded-superconducting-shield techniques and is maintained with the aid of a magnetic materials control program. A high performance magnetic shield system is required for the proper function of gyroscope readout. The readout system employs a dc SQUID to measure the London moment generated by the superconducting gyro rotor in order to resolve sub-milliarcsecond changes in the gyro spin direction. In addition to a low residual dc magnetic field, attenuation of external field variation is required to be 1012 at the gyro positions. We discuss the measurement of the dc magnetic field and ac attenuation factor and the performance of the readout system.
  • Journal title
    Advances in Space Research
  • Serial Year
    2000
  • Journal title
    Advances in Space Research
  • Record number

    1126752