• Title of article

    First MAGDAS installation at Fayum in Egypt Original Research Article

  • Author/Authors

    A. Mahrous، نويسنده , , E. Ghamry، نويسنده , , R. Elhawary، نويسنده , , I. Fathy، نويسنده , , Y. Yamazaki، نويسنده , , Donato S. Abe، نويسنده , , T. Uozumi، نويسنده , , K. Yumoto، نويسنده ,

  • Issue Information
    دوهفته نامه با شماره پیاپی سال 2010
  • Pages
    5
  • From page
    613
  • To page
    617
  • Abstract
    We have installed the first MAGDAS magnetometer at Fayum in Egypt. The ambient temperature in the initial sensor house varied more than ±4 °C in one day (24 h period). This variation made the magnetic data useless. To correct this problem, (1) a new sensor house was re-constructed which reduced the diurnal variation to less than ±1 °C, and (2) the “Uozumi Temperature Correction Method” was introduced. As a result, good data is now arriving in real time at a central facility in Japan.
  • Keywords
    MAGDAS/CPMN , MAGDAS magnetometer , Temperature drift
  • Journal title
    Advances in Space Research
  • Serial Year
    2010
  • Journal title
    Advances in Space Research
  • Record number