Title of article
Synthetic Doppler spectroscopy and curvilinear camera diagnostics in the ERO code Original Research Article
Author/Authors
T. Makkonen، نويسنده , , M. Groth، نويسنده , , M.I. Airila، نويسنده , , R. Dux، نويسنده , , A. Janzer، نويسنده , , T. Kurki-Suonio، نويسنده , , T. Lunt، نويسنده , , H.W. Mueller، نويسنده , , T. Puetterich، نويسنده , , E. Viezzer، نويسنده , , ASDEX Upgrade team، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2013
Pages
6
From page
1842
To page
1847
Abstract
We present a set of new synthetic diagnostics, recently implemented in the ERO code, that were developed to facilitate direct comparisons between experiments and modeling of tokamak scrape-off-layer plasmas. The diagnostics calculate the spectroscopic Doppler shift and Doppler broadening of impurity lines of interest for any line of sight, and they also generate camera images from arbitrary viewing angles allowing for curvilinear (e.g., wide-angle or fisheye) lenses. The synthetic camera diagnostics can either replicate the distortions caused by curvilinear lenses or create a rectilinear synthetic camera image and correct the curvilinear distortions in the experimental image. Comparison to experimental data is presented.
Keywords
Curvilinear , distortion , Fusion , Plasma , Impurity , Spectroscopy , Camera
Journal title
Computer Physics Communications
Serial Year
2013
Journal title
Computer Physics Communications
Record number
1136603