Title of article :
Fracture toughness and residual stress measurements in tempered glass by Hertzian indentation Original Research Article
Author/Authors :
F. Petit-Coviaux، نويسنده , , A.C. Sartieaux، نويسنده , , M. Gonon، نويسنده , , F. Cambier، نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2007
Pages :
10
From page :
2765
To page :
2774
Abstract :
Hertzian indentation was used to assess the fracture toughness (KIc) and the surface residual stresses of tempered soda lime glass. Although such measurements are usually performed on chemically strengthened glasses, where the thickness of the layer under compression is limited to several micrometres, our study considers the most useful case of thermally quenched glass, widely used in industry and where the compressed layer is several hundred micrometres thick. Measurements were performed on annealed and thermally quenched samples and residual stresses were calculated using two different models of the literature. Results were compared to stress measurements performed by a conventional photoelasticimetry technique. It is shown that Hertzian indentation gives qualitatively correct results which are comparable for each of the literature models used, provided that interfacial friction between the spherical indenter and substrate is correctly taken into account in the calculations. It is shown that a scratch tester used to perform sliding indentation onto the surface of the samples is a suitable tool for assessing the friction coefficient value.
Keywords :
Hertzian indentation , Glass , Quenching , Residual stresses , Toughness
Journal title :
ACTA Materialia
Serial Year :
2007
Journal title :
ACTA Materialia
Record number :
1142977
Link To Document :
بازگشت