Title of article :
Development of rapid response thermocouple probes for use in a batch ohmic heating system Original Research Article
Author/Authors :
Margaret M. Zell، نويسنده , , J.G. Lyng، نويسنده , , D.J. Morgan ، نويسنده , , D.A. Cronin، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
4
From page :
344
To page :
347
Abstract :
Temperature mapping during batch ohmic heating is a challenging but critically important task. It is essential to be able to monitor temperature changes at various, selected locations within a food to ensure a safe cooking process. Thermocouple probes of various designs and sizes were assembled and evaluated in order to develop thin, robust, fully insulated and rapid measurement devices. The response time of each probe was measured, and the accuracy and precision of the thermocouple probes were evaluated using established procedures. The most satisfactory thermocouple probe for application in a batch ohmic heating system was found to be a triple-point probe with a fully insulated stainless steel sheath having an outer diameter of 2 mm, an internal diameter of 1.5 mm and a response time of 0.6 s.
Keywords :
Temperature measurement , Thermocouple probe design , Ohmic heating
Journal title :
Journal of Food Engineering
Serial Year :
2009
Journal title :
Journal of Food Engineering
Record number :
1168295
Link To Document :
بازگشت