Title of article :
High-pressure destruction kinetics of Clostridium sporogenes ATCC 11437 spores in milk at elevated quasi-isothermal conditions Original Research Article
Author/Authors :
Hosahalli S. Ramaswamy، نويسنده , , Yanwen Shao، نويسنده , , Songming Zhu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
249
To page :
257
Abstract :
The high-pressure sterilization establishment requires data on isobaric and isothermal destruction kinetics of baro-resistant pathogenic and spoilage bacterial spores. In this study, Clostridium sporogenes 11437 spores (107 CFU/ml) inoculated in milk were subjected to different pressure, temperature and time (P, T, t) combination treatments (700–900 MPa; 80–100 °C; 0–32 min). An insulated chamber was used to enclose the test samples during the treatment for maintaining isobaric and quasi-isothermal processing conditions. Decimal reduction times (D values) and pressure and temperature sensitivity parameters, ZT (pressure constant) and ZP (temperature constant) were evaluated using a 3 × 3 full factorial experimental design. HP treatments generally demonstrated a minor pressure pulse effect (PE) (no holding time) and the pressure hold time effect was well described by the first order model (R2 > 0.90). Higher pressures and higher temperatures resulted in a higher destruction rate and a higher microbial count reduction. At 900 MPa, the temperature corrected D values were 9.1, 3.8, 0.73 min at 80, 90, 100 °C, respectively. The thermal treatment at 0.1 MPa resulted in D values 833, 65.8, 26.3, 6.0 min at 80, 90, 95, 100 °C respectively. By comparison, HP processing resulted in a strong enhancement of spore destruction at all temperatures. Temperature corrected ZT values were 16.5, 16.9, 18.2 °C at 700, 800, 900 MPa, respectively, which were higher than the thermal z value 9.6 °C. Hence, the spores had lower temperature sensitivity at elevated pressures. Similarly, corrected ZP values were 714, 588, 1250 MPa at 80, 90, 100 °C, respectively, which illustrated lower pressure sensitivity at higher temperatures. By general comparison, it was concluded that within the range operating conditions employed, the spores were relatively more sensitive to temperature than to pressure.
Keywords :
Clostridium sporogenes , High-pressure , Sterilization , Spore inactivation , Food safety , kinetics
Journal title :
Journal of Food Engineering
Serial Year :
2010
Journal title :
Journal of Food Engineering
Record number :
1168491
Link To Document :
بازگشت