Title of article :
Experimental investigation on the sound pressure level for a high thermal capacity burner during a running cycle
Author/Authors :
Vlad Iordache، نويسنده , , Tiberiu Catalina، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
10
From page :
708
To page :
717
Abstract :
In many research or technical expertise studies the maximum noise level of a boiler is associated with the maximum thermal load of the burner. However, this type of air injected burners presents a complex running cycle with different functioning periods, where different parts (engine, fan, flame) of the burner are running separately or in the same time. In this study we are focused on the analysis, by experimental measurements, of the entire functioning cycle of a boiler by pointing out the noise differences and their importance when doing an experimental acoustical investigation. The entire 1/3 octave spectrum of the sound pressure level (SPL) was recorded during a complete running cycle by means of logging software associated to the sound meter. The sound equivalent level was calculated for each period of the running cycle and compared to the norms and with two theoretical prediction models that take into account the heating power and the boiler room volume. It was found that the most accurate data are obtained when the measurements are done in one-third octave. The maximum noise level was established to be not for the maximum thermal load period, but for the ventilation period of the boiler (before gas injection) with 82.1 dB at 125 Hz. A shut down delay was detected at the end of the cycle with 13 s for higher frequencies, due to the vibration of the boiler parts. Two 3D graphical representations point out the most important frequencies characterizing each running state of the burner. Compared to the noise curve (NC85) the minimum differences between the admissible values and the ones produced by the burner were found to be around 5.5 dB and therefore no acoustical treatment was needed. The results of the SPL prediction models matched the experimental data only for some of the boiler cycle periods and for only some of the frequencies. This type of detailed experiment investigation of the burner noise highlights the periods of the running cycle and the frequencies where the noise level requires acoustical treatment.
Keywords :
Sound pressure level , Running cycle , Experimental campaign , Gas burner
Journal title :
Applied Acoustics
Serial Year :
2013
Journal title :
Applied Acoustics
Record number :
1171803
Link To Document :
بازگشت