Title of article :
Influence of buffer on resonance frequency of thermoacoustic engine Original Research Article
Author/Authors :
G.B. Chen، نويسنده , , J.P Jiang، نويسنده , , J.L. Shi، نويسنده , , T Jin، نويسنده , , K Tang، نويسنده , , Y.L. Jiang، نويسنده , , N Jiang، نويسنده , , Y.H. Huang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
5
From page :
223
To page :
227
Abstract :
Frequency matching is of great importance to a thermoacoustically driven pulse tube refrigeration system. To compute the resonance frequency of thermoacoustic engines, the fluid impedance method is introduced. The calculations of the thermoacoustic engines with different arrangements of buffer have been carried out. The influence of the buffer arrangements and the volume on the resonance frequency as well as the acoustic power of thermoacoustic engines is also discussed.
Keywords :
Pulse tube refrigeration , Thermoacoustic engine , Frequency matching
Journal title :
Cryogenics
Serial Year :
2002
Journal title :
Cryogenics
Record number :
1172244
Link To Document :
بازگشت