Title of article :
Performance improvement of a two-stage GM cryocooler by use of Er(Ni0.075Co0.925)2 magnetic regenerator material Original Research Article
Author/Authors :
L Trevisani، نويسنده , , T Kuriyama، نويسنده , , F Negrini، نويسنده , , T Okamura، نويسنده , , Y Ohtani، نويسنده , , M Okamura، نويسنده , , M Fabbri، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
A newly developed magnetic regenerator material Er(Ni0.075Co0.925)2, having high specific heat at temperatures from 10 to 20 K, has been tested inside the second regenerator of a two-stage GM cryocooler. Different working conditions have been examined: four Er(Ni0.075Co0.925)2/Pb material ratios, three displacer reciprocating speeds, and two cryocooler stroke lengths. In the best working conditions, the experimental results show a cooling power improvement up to 15% over the whole temperature range from 10 to 20 K compared to that of the same GM cryocooler employing only lead.
Keywords :
GM cryocooler , Magnetic regenerator material , Regenerator
Journal title :
Cryogenics
Journal title :
Cryogenics