Title of article
Transient testing of perforated plate matrix heat exchangers Original Research Article
Author/Authors
K. Krishnakumar، نويسنده , , G. Venkatarathnam، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
9
From page
101
To page
109
Abstract
Till recently, perforated plate matrix heat exchangers (MHEs) were used mainly in helium liquefaction systems and Brayton cycle refrigerators. Currently they are also being used in Kleemenko or J-T refrigerators operating with a mixture of gases. It is now well understood that the effectiveness of a MHE is strongly dependent on the number of plate–spacer pairs used. It has also been shown that the traditional methods used for reducing the transient single blow method to determine the heat transfer coefficients cannot be used for MHEs.
In this paper we show that the traditional methods can indeed be used for determining the heat transfer coefficients using the transient testing methods, provided certain conditions are met.
Keywords
Heat exchangers , Heat transfer coefficient , Transient testing
Journal title
Cryogenics
Serial Year
2003
Journal title
Cryogenics
Record number
1172319
Link To Document