• Title of article

    Connecting hose’s operating characteristics and its effect on the cooling performance of an 80 K Oxford split-Stirling-cycle cryocooler Original Research Article

  • Author/Authors

    C.Q. Zhang، نويسنده , , Y.N. Wu، نويسنده , , L. Xu، نويسنده , , D.Y. Liu، نويسنده , , Y.S. Chen، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    10
  • From page
    335
  • To page
    344
  • Abstract
    In this paper, a mathematical model on the connecting hose of a one-stage Oxford split-Stirling cryocooler has been made to simulate its dynamic performance. A set of governing equations has been discretized by method of characteristics and dissolved by a numerical method. The present paper emphasizes the validation of this model against experimental results of pressure phase lag and amplitude attenuation through connecting hose, and cooler performance vs. connecting hose in different dimensions. The comparison shows acceptable agreement between the simulation and experimental results.
  • Keywords
    Oxford split-Stirling cryocooler , Connecting hose , Characteristics , Cooler performance
  • Journal title
    Cryogenics
  • Serial Year
    2003
  • Journal title
    Cryogenics
  • Record number