Title of article :
Capacitance based mass metering for cryogenic fluids Original Research Article
Author/Authors :
Mark A. Nurge، نويسنده , , Robert Youngquist، نويسنده , , Deron Walters، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
6
From page :
501
To page :
506
Abstract :
This paper describes a method for measuring the mass of cryogenic fluids in on-board rocket propellant tanks or ground storage tanks. Linear approximations to the Clausius–Mossotti relationship serve as the foundation for a capacitance based mass sensor, regardless of fluid density stratification or tank shape. Sensor design considerations are presented along with the experimental results for a capacitance based mass gage tested in liquid nitrogen. This test data is shown to be consistent with theory resulting in a demonstrated mass measurement accuracy of ±0.75% and a deviation from linearity of less than ±0.30% of full scale mass. Theoretical accuracies are also shown to be ±0.73% for hydrogen and ±1.39% for oxygen for a select range of pressures and temperatures.
Keywords :
Hydrogen (B) , Nitrogen (B) , Oxygen (B) , Dielectric properties (C) , Instrumentation (D)
Journal title :
Cryogenics
Serial Year :
2003
Journal title :
Cryogenics
Record number :
1172364
Link To Document :
بازگشت