• Title of article

    Experimental study on natural circulation precooling of cryogenic pump system with gas phase inlet reflux configuration Original Research Article

  • Author/Authors

    G.B. Chen، نويسنده , , Y.K. Zhong، نويسنده , , X.L. Zheng، نويسنده , , Q.F. Li، نويسنده , , X.M. Xie، نويسنده , , Z.H Gan، نويسنده , , Y.H. Huang، نويسنده , , K. Tang، نويسنده , , L. B. Kong، نويسنده , , L.M. Qiu، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    6
  • From page
    693
  • To page
    698
  • Abstract
    A novel gas-phase inlet configuration in the natural circulation system instead of the liquid-phase inlet is introduced to cool down a cryogenic pump system from room temperature to cryogenic temperatures, effectively. The experimental apparatus is illustrated and test process is described. Heat transfer and pressure drop data during the cool-down process are recorded and portrayed. By contrast with liquid-phase inlet configuration, experimental results demonstrate that the natural circulation with the gas-phase inlet configuration is an easier and more controllable way to cool down the pump system and maintain it at cryogenic temperatures.
  • Keywords
    Liquid transfer , Cryogenic pump , Natural circulation precooling
  • Journal title
    Cryogenics
  • Serial Year
    2003
  • Journal title
    Cryogenics
  • Record number