Title of article :
Quench detection method without a central voltage tap by calculating active power Original Research Article
Author/Authors :
N. Nanato، نويسنده , , K. Nakamura، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
In this paper, we present an electric quench detection method without a central voltage tap which may cause the short-circuit of the lead-wires from the voltage taps in the quench detection of a large AC superconducting coil. In this method, an inductive voltage detection coil is used instead of the central voltage tap. The inductive voltage detection coil is electrically insulated from a superconducting coil and therefore the lead-wires do not break down. Through the quench detection tests for a Bi-2223/Ag HTS coil, we show the feasibility of the proposed method for detecting the quench of the large AC superconducting coil.
Keywords :
AC superconducting coil , Quench detection , Inductive voltage detection
Journal title :
Cryogenics
Journal title :
Cryogenics