Title of article :
Observation and control of temperature instabilities in a four-valve pulse tube refrigerator Original Research Article
Author/Authors :
P. Waldauf، نويسنده , , M Thürk، نويسنده , , P Seidel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
5
From page :
75
To page :
79
Abstract :
The use of a pulse tube cryocooler in an application requires temperature stability at the cold end. In our four-valve pulse tube refrigerator we have observed long-term temperature instabilities lasting some days and short-term instabilities lasting some hours or even minutes. Investigations have shown that the latter anomaly is caused by the dc-flow. The negative influence on the stability is due to an additional mass flow (dc-flow) to the cold end of the pulse tube, which results in a parasitic heat input. In this paper we present an actively controlled dc-flow suppression device, which uses a temperature gradient in the regenerator as a control parameter. This device enables us to eliminate the temperature instabilities.
Keywords :
Stability (C) , Pulse tube (E)
Journal title :
Cryogenics
Serial Year :
2004
Journal title :
Cryogenics
Record number :
1172404
Link To Document :
بازگشت