Title of article
Ramp-rate limitation experiment using induced current method. Part 2: analysis Original Research Article
Author/Authors
Sangkwon Jeong، نويسنده , , Makoto Takayasu، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
6
From page
109
To page
114
Abstract
This paper describes an analysis of ramp-rate limitation experiments performed by a background magnet only without a power supply for the tested cable. Three-strand U-shape cable-in-conduit conductor samples show distinctive ramp-rate limitation phenomena with sensitive transition between no-quench and quench results. Quench experimental results at various ramp rates are explained by a representative induced loop current model. Since the sample length is less than 1 m and the loop resistance through the joint is an order of 1 μΩ, the dominant loop current is induced mostly through the joint. Multiple quench-recovery processes during continuous magnetic field ramp are also explained due to fast recovery of the sample after quench. It is experimentally observed that the strand heat flux condition can be very influential to determine quench-recovery process near the critical heat flux regime of liquid helium.
Keywords
Ramp-rate limitation , Cable-in-conduit conductor , Single-induced loop current model
Journal title
Cryogenics
Serial Year
2004
Journal title
Cryogenics
Record number
1172408