Title of article :
Investigation on vapor-cooled current leads operating in a pulse mode Original Research Article
Author/Authors :
Sangkwon Jeong، نويسنده , , Sehwan Park، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
8
From page :
241
To page :
248
Abstract :
This paper describes transient numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas flow and a copper lead with temperature dependent properties of helium gas, copper and stainless steel. The numerical analysis was validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor calculation and the effect of intermediate cooling are presented for the current leads under pulse operation, which can significantly reduce heat input to a cryostat.
Keywords :
Overloading factor , Pulse mode operation , Vapor cooled current leads
Journal title :
Cryogenics
Serial Year :
2004
Journal title :
Cryogenics
Record number :
1172427
Link To Document :
بازگشت