A 115 K thermoacoustically driven pulse tube refrigerator with low onset temperature Original Research Article
Author/Authors :
K. Tang، نويسنده , , G.B. Chen، نويسنده , , L. B. Kong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
5
From page :
287
To page :
291
Abstract :
After the modifications of jacket type water coolers and stacks, and the optimizations of the openings of orifice and double inlet valves, a refrigeration temperature as low as 115.4 K has been achieved by a thermoacoustically driven pulse tube refrigerator. By operating the double inlet valve of the pulse tube refrigerator, the onset temperature of the thermoacoustic system decreases from 550 to 340 °C. It provides the possibility of utilizing the low-grade heat energy.
Keywords :
Pulse tube refrigerator , Thermoacoustic prime mover , Thermoacoustic refrigeration