Title of article :
An uncertainty analysis of the PVT gauging method applied to sub-critical cryogenic propellant tanks Original Research Article
Author/Authors :
Neil T. Van Dresar، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
9
From page :
515
To page :
523
Abstract :
The PVT (pressure, volume, temperature) method of liquid quantity gauging in low-gravity is based on gas law calculations assuming conservation of pressurant gas within the propellant tank and the pressurant supply bottle. There is interest in applying this method to cryogenic propellant tanks since the method requires minimal additional hardware or instrumentation. To use PVT with cryogenic fluids, a non-condensable pressurant gas (helium) is required. With cryogens, there will be a significant amount of propellant vapor mixed with the pressurant gas in the tank ullage. This condition, along with the high sensitivity of propellant vapor pressure to temperature, makes the PVT method susceptible to substantially greater measurement uncertainty than is the case with less volatile propellants. A conventional uncertainty analysis is applied to example cases of liquid hydrogen and liquid oxygen tanks. It appears that the PVT method may be feasible for liquid oxygen. Acceptable accuracy will be more difficult to obtain with liquid hydrogen.
Keywords :
Cryogenic propellants , Low-gravity , Gauging
Journal title :
Cryogenics
Serial Year :
2004
Journal title :
Cryogenics
Record number :
1172461
Link To Document :
بازگشت