Title of article :
Critical heat flux on a flat plate heater located at the middle of a duct in forced flow of pressurized He II Original Research Article
Author/Authors :
T Okamura، نويسنده , , M Saeki، نويسنده , , K Hata، نويسنده , , K Hama، نويسنده , , Y Shirai، نويسنده , , M Shiotsu، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
7
From page :
603
To page :
609
Abstract :
Critical heat fluxes (CHFs) were measured for two types of rectangular ducts containing horizontal flat plate heaters. One has the flat plate heater of 6 mm wide and 20 mm long located on the inner lower wall at 50 mm from the inlet. The other duct has two horizontal flat plates of 6 mm wide and 20 mm long on inner upper and lower walls at 50 mm from the inlet. The equation of CHF for the forced convection containing a new nondimensional-parameter m introduced in order to calculate cross-sectionally averaged liquid temperature at the center of the duct was derived based on two fluid model, ordinary convection theorem and experimental results. It was confirmed that this correlation can describe not only the authorʹs data on the duct but also other workerʹs data for channels with different shapes and sizes.
Keywords :
Forced convection , Superfluid , Critical heat flux
Journal title :
Cryogenics
Serial Year :
2004
Journal title :
Cryogenics
Record number :
1172472
Link To Document :
بازگشت