Title of article :
Experimental tests and modeling of the optimal orifice size for a closed cycle 4He sorption refrigerator Original Research Article
Author/Authors :
J. Lau، نويسنده , , M. Benna، نويسنده , , M. Devlin، نويسنده , , S. Dicker، نويسنده , , L. Page، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Closed cycle 4He sorption refrigerators are an increasingly popular choice for remote cryogenic operations. The presence of a superfluid film on the inner walls of the evaporation pot limits their performance. We present a simple model of the gas, film, and heat flow in a 4He sorption refrigerator, taking into account the effects of an orifice to limit superfluid film flow. The model serves as a useful guideline for optimizing cryogenic performance. We also present a diagram of hold time vs. steady state temperature as a function of the radius of the orifice and compare the model to measurements.
Keywords :
Sorption coolers (E) , Superfluid helium (He II) (B) , He II systems (E)
Journal title :
Cryogenics
Journal title :
Cryogenics