Title of article :
Effect of different treatments of copper surface on its total hemispherical absorptivity bellow 77 K Original Research Article
Author/Authors :
V. Musilova، نويسنده , , T. Kralik، نويسنده , , P. Hanzelka، نويسنده , , A. Srnka، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
257
To page :
261
Abstract :
Total hemispherical absorptivity of copper surfaces treated with standard industrial methods was measured in dependence on the temperature of thermal radiation, varying from 25 K to 300 K. The sample temperature was typically from 5 K to 40 K and did not exceed 70 K. Usability of chemical and mechanical Cu surface finishing as well as Cu plating with Ni and Au for cryogenic design is discussed. As an example of practical application of our results, the cryogenic design of a LN2 trap is presented.
Keywords :
Metals (A) , Radiant properties (C) , Heat Transfer (C) , Cryostats (F) , Structural materials (A)
Journal title :
Cryogenics
Serial Year :
2007
Journal title :
Cryogenics
Record number :
1172756
Link To Document :
بازگشت