Title of article :
Investigation of the effects of three key parameters on the heat transfer capability of a CLHP Original Research Article
Author/Authors :
Qing Mo، نويسنده , , Jingtao Liang، نويسنده , , Jinghui Cai، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
5
From page :
262
To page :
266
Abstract :
A cryogenic loop heat pipe (CLHP) has been developed for future aerospace applications at the TIPC (Technical Institute of Physics and Chemistry). The device has been tested in different situations with constant heat sink temperature of about 78 K. The effects of the reservoir volume and the pore size of the primary wick on the performance of CLHP were investigated. With a wick pore size of 2 μm, the CLHP can transfer a heat load of 26 W under horizontal orientation no matter what size of the reservoir volume being used. On the contrary, when the pore size was large (10 μm), the heat transfer capability of the CLHP can be up to 26 W only when a smaller reservoir (60 cc) was used, and its ability to operate against gravity was greatly weakened. Moreover, when the working fluid was oxygen instead of nitrogen, the heat transfer capability can be up to 50 W under horizontal orientation with the other experimental conditions remaining the same.
Keywords :
Cryogenic loop heat pipe , Liquid-nitrogen temperature , Heat transfer capability , Capillary pressure
Journal title :
Cryogenics
Serial Year :
2007
Journal title :
Cryogenics
Record number :
1172757
Link To Document :
بازگشت