Title of article :
Investigation on a thermal-coupled two-stage Stirling-type pulse tube cryocooler Original Research Article
Author/Authors :
Luwei Yang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
5
From page :
492
To page :
496
Abstract :
Multi-stage Stirling-type pulse tube cryocoolers with high frequency (30–60 Hz) are one important direction in recent years. A two-stage Stirling-type pulse tube cryocooler with thermally coupled stages has been designed and established two years ago and some results have been published. In order to study the effect of first stage precooling temperature, related characteristics on performance are experimentally investigated. It shows that at high input power, when the precooling temperature is lower than 110 K, its effect on second stage temperature is quite small. There is also the evident effect of precooling temperature on pulse tube temperature distribution; this is for the first time that author notice the phenomenon. The mean working pressure is investigated and the 12.8 K lowest temperature with 500 W input power and 1.22 MPa average pressure have been gained, this is the lowest reported temperature for high frequency two-stage PTCS. Simulation has reflected upper mentioned typical features in experiments.
Keywords :
Staging-method , E. Pulse tube , E. Cycle optimization , E. Regenerator
Journal title :
Cryogenics
Serial Year :
2008
Journal title :
Cryogenics
Record number :
1172877
Link To Document :
بازگشت