    Hydrodynamic parameters of mesh fillers relevant to miniature regenerative cryocoolers Original Research Article

  • Author/Authors

    E.C. Landrum، نويسنده , , T.J. Conrad، نويسنده , , S.M. Ghiaasiaan، نويسنده , , Carl S. Kirkconnell، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    8
  • From page
    373
  • To page
    380
  • Abstract
    Directional hydrodynamic parameters of two fine-mesh porous materials that are suitable for miniature regenerative cryocoolers were studied under steady and oscillating flows of helium. These materials included stacked discs of #635 stainless steel (wire diameter of 20.3 μm) and #325 phosphor bronze (wire diameter of 35.6 μm) wire mesh screens, which are among the commercially available fillers for use in small-scale regenerators and heat exchangers, respectively. Experiments were performed in test sections in which pressure variations across these fillers, in the axial and lateral (radial) directions, were measured under steady and oscillatory flows. The directional permeability and Forchheimer’s inertial coefficient were then obtained by using a Computational Fluid Dynamics (CFD)-assisted method. The oscillatory flow experiments covered a frequency range of 50–200 Hz. The results confirmed the importance of anisotropy in the mesh screen fillers, and indicated differences between the directional hydrodynamic resistance parameters for steady and oscillating flow regimes.
  • Keywords
    Oscillatory flow , Friction factor , Forchheimer’s inertial coefficient , Darcy permeability , steady flow