Title of article :
A 300 Hz two-stage pulse tube cryocooler that attains 58 K
Author/Authors :
Huikun Cai، نويسنده , , Luwei Yang، نويسنده , , Ercang Luo a، نويسنده , , Yuan Zhou، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
3
From page :
469
To page :
471
Abstract :
We present a two-stage pulse tube cryocooler working at 300 Hz driven by a thermoacoustic engine. Compared to the previous experimental results, the combined inertance tube with different diameters that is used in the second stage is found to play the key role in phase shifting and to lead to superior cooling. Two different wall thickness tubes are tested in the experiments. After the optimization, the second-stage cold end achieves a no-load temperature of 57.9 K with an average pressure of 3.8 MPa, and a cooling capacity of 0.5 W at 81.88 K.
Journal title :
Cryogenics
Serial Year :
2010
Journal title :
Cryogenics
Record number :
1173076
Link To Document :
بازگشت