Title of article
Experimental investigation on mixed refrigerant Joule–Thomson cryocooler with flammable and non-flammable refrigerant mixtures Original Research Article
Author/Authors
N.S. Walimbe، نويسنده , , K.G. Narayankhedkar، نويسنده , , M.D Atrey، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2010
Pages
7
From page
653
To page
659
Abstract
The mixed refrigerant Joule–Thomson (MR J–T) cryocoolers have a wide application area covering the temperature range from 80 K to 200 K. The significant advantages of the system are simplicity of its design and working reliability with high level performance. The present paper discusses the experimental results of MR J–T cooler with different flammable and non-flammable mixture compositions. The work highlights the use of pressure–enthalpy and temperature–enthalpy diagrams for these mixtures to support the experimental results. A record lowest temperature of 65 K and a cooling capacity of 6 W at 80 K are obtained for a single stage MR J–T system starting at 300 K. Further, using a mixture of minimum flammable refrigerants, temperatures below 100 K is achieved.