Title of article :
Development of a non-intrusive heat transfer coefficient gauge and its application to high pressure die casting: Effect of the process parameters
Author/Authors :
G. Dour، نويسنده , , M. Dargusch، نويسنده , , C. Davidson، نويسنده , , A. Nef، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
11
From page :
223
To page :
233
Abstract :
A heat transfer coefficient gauge has been built, obeying particular rules in order to ensure the relevance and accuracy of the collected information. The gauge body is made out of the same materials as the die casting die (H13). It is equipped with six thermocouples located at different depths in the body and with a sapphire light pipe. The light pipe is linked to an optic fibre, which is connected to a monochromatic pyrometer. Thermocouples and pyrometer measurements are recorded with a data logger. A high pressure die casting die was instrumented with one such gauge. A set of 150 castings was done and the data recorded. During the casting, some process parameters have been modified such as piston velocity, intensification pressure, delay before switch to the intensification stage, temperature of the alloy, etc. … The data was treated with an inverse method in order to transform temperature measurements into heat flux density and heat transfer coefficient plots. The piston velocity and the initial temperature of the die seem to be the process parameters that have the greatest influence on the heat transfer.
Keywords :
Heat transfer , Heat flux density , Heat transfer coefficient , Instrumented die , High pressure die casting , Die casting
Journal title :
Journal of Materials Processing Technology
Serial Year :
2005
Journal title :
Journal of Materials Processing Technology
Record number :
1179725
Link To Document :
بازگشت