Title of article
Measurement of the mass transfer coefficient at workpiece surfaces in heat treatment furnaces
Author/Authors
Weimin Gao ، نويسنده , , Lingxue Kong، نويسنده , , John M. Long، نويسنده , , Peter D. Hodgson، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
9
From page
497
To page
505
Abstract
The mass (e.g. carbon) transfer coefficient at a workpiece surface is an important kinetic factor to control the heat treatment process of the workpiece and to evaluate heat treatment equipment. The coefficient can be calculated from the carbon concentration at the surface of a sample carburized in a carburizing furnace for a given time. Two common measurement methods which use a thin plate and employ a component as samples respectively are evaluated and compared for sensitivity and uncertainty. The comparison shows that the use of a component produces higher measurement precision and also has the advantage in measuring the carbon transfer coefficients at different treated positions. This method is then extended and discussed methodologically. Also two equations are proposed to calculate the carbon transfer coefficient and its uncertainty, respectively. This method is also applied to measure the carbon transfer coefficient in a fluidized bed heat treatment furnace.
Keywords
Carburizing , Heat treatment , Mass transfer coefficient , measurement , Uncertainty , Sensitivity analysis
Journal title
Journal of Materials Processing Technology
Serial Year
2009
Journal title
Journal of Materials Processing Technology
Record number
1182603
Link To Document