Title of article
Reliability assessment of passive isolation condenser system of AHWR using APSRA methodology
Author/Authors
A.K. Nayak، نويسنده , , Vikas Jain، نويسنده , , M.R. Gartia، نويسنده , , Hari Prasad، نويسنده , , A. Anthony، نويسنده , , S.K. Bhatia، نويسنده , , R.K. Sinha، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
12
From page
1064
To page
1075
Abstract
In this paper, a methodology known as APSRA (Assessment of Passive System ReliAbility) is used for evaluation of reliability of passive isolation condenser system of the Indian Advanced Heavy Water Reactor (AHWR). As per the APSRA methodology, the passive system reliability evaluation is based on the failure probability of the system to perform the design basis function. The methodology first determines the operational characteristics of the system and the failure conditions based on a predetermined failure criterion. The parameters that could degrade the system performance are identified and considered for analysis. Different modes of failure and their cause are identified. The failure surface is predicted using a best estimate code considering deviations of the operating parameters from their nominal states, which affect the isolation condenser system performance. Once the failure surface of the system is predicted, the causes of failure are examined through root diagnosis, which occur mainly due to failure of mechanical components. Reliability of the system is evaluated through a classical PSA treatment based on the failure probability of the components using generic data.
Keywords
Passive systems , Safety , Failure surface , reliability , Isolation condenser
Journal title
Reliability Engineering and System Safety
Serial Year
2009
Journal title
Reliability Engineering and System Safety
Record number
1188002
Link To Document