Title of article :
Feasibility study and uncertainties in the validation of an existing safety-related control circuit with the ISO 13849-1:2006 design standard
Author/Authors :
Sabrina Jocelyn، نويسنده , , James Baudoin، نويسنده , , Yuvin Chinniah، نويسنده , , Philippe Charpentier، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
9
From page :
104
To page :
112
Abstract :
In industry, machine users and people who modify or integrate equipment often have to evaluate the safety level of a safety-related control circuit that they have not necessarily designed. The modifications or integrations may involve work to make an existing machine that does not comply with normative or regulatory specifications safe. However, how can a circuit performing a safety function be validated a posteriori? Is the validation exercise feasible? What are the difficulties and limitations of such a procedure? The aim of this article is to answer these questions by presenting a validation study of a safety function of an existing machine. A plastic injection molding machine is used for this study, as well as standard ISO 13849-1:2006. Validation consists of performing an a posteriori (post-design) estimation of the performance level of the safety function. The procedure is studied for two contexts of use of the machine: in industry, and in laboratory. The calculations required by the ISO standard were done using Excel, followed by SIStema software. It is shown that, based on the context of use, the estimated performance level was different for the same safety-related circuit. The variability in the results is explained by the assumptions made by the person undertaking the validation without the involvement of the machine designer.
Keywords :
Machine , Safety function , failure , Performance level , Control system
Journal title :
Reliability Engineering and System Safety
Serial Year :
2014
Journal title :
Reliability Engineering and System Safety
Record number :
1188771
Link To Document :
بازگشت